Agilent 1100 G1314A Variable Wavelength Detector

Category:
Chromatography
Manufacturer:
Agilent
Listing #:
AGILENT1100G1314AVWD-6181
Ships Within:
3 Business Days
Price:
$2,999.00

REQUEST QUOTE

or Call 617-999-5746 for more information

"Want to sell your item like this one?"

  • EQUIPMENT DESCRIPTION
  • SPECIFICATIONS
  • INCLUDED
  • NOTES

The Agilent 1100 G1314A Variable Wavelength Detector provides a variable wavelength detection solution for use as a component of a Agilent 1100 HPLC Stack, or independently through a controlling PC. This Variable Wavelength Detector has a wavelength range of between 190-600 nm, and features an easy access design that allows users to quickly change a deuterium lamp, or a flow cell. The optical system of this VWD passes the light through a lens, a holmium oxide filter, an entrance slit, then through to a spherical mirror where it bounces to a grating assembly. After the grating assembly light then hits a second mirror, to a beam splitter and finally the flow cell where UV absorption takes place and onto a sample diode to convert to an electrical signal to report back to the system for analysis. This VWD can be operated through a controlling PC through the RS232C connection, or through the GPIB connector.

Agilent 1100 G1314A Variable Wavelength Detector Specifications:

Detection type

Double-beam photometer

Light source

Deuterium lamp

Wavelength range

190–600 nm

Short term noise (ASTM)

± 0.75 × 10-5 AU at 254 nm

Drift

3 × 10-4 AU/hr at 254 nm

Linearity

> 2 AU (5%) upper limit

Wavelength accuracy

± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter

Band width

6.5 nm typical

Flow cells

Standard: 14-µl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum High pressure: 14-µl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum Micro: 1-µl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum Semimicro: 5-µl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum

Analog outputs

Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, one output

Dimensions

18x14x6"

Weight

25 lbs 

Power

100-120/220-240V, 50/60 Hz, 220 VA

  • Agilent G1314A Variable Wavelength Detector
  • 120V Power Cord
  • System Validation Report with Clean Bill of Health
  • 30-Day Warranty

This Agilent 1100 G1314A Variable Wavelength Detector has been fully inspected and is operating without issue. All of our lab equipment comes backed with our standard warranty. 

Other Chromatography