Agilent 1100 Series G1314A Variable Wavelength Detector
Chromatography
Agilent
- EQUIPMENT DESCRIPTION
- SPECIFICATIONS
- INCLUDED
- NOTES
The Agilent G1314A VWD 1100 Series is a high performance Variable Wavelength Detector, that can be used independently or added as a component to a 1100 HPLC system. This VWD employs a deuterium lamp that provides high intensity and a low detection limit, with a wavelength range of 190-600 nm. The optical system of this HPLC detector passes the light beam through a lens, holmium oxide filter, entrance slit, then to a spherical mirror where it bounces to a grating assembly, then a second mirror, to a beam splitter and finally the flow cell where UV absorption takes place and onto a sample diode to convert to an electrical signal. The grating assembly of this HPLC component uses a stepper motor, that allows for rapid changes of the wavelength to suit your application. The Agilent VWD is easy to access through a front panel, that allows you to quickly get to the lamp or replace a flow cell. This VWD can be operated through a controlling PC through the RS232C connection, or through the GPIB connector.
Agilent G1314A VWD Detector Specifications:
Detection type | Double-beam photometer |
Light source | Deuterium lamp |
Wavelength range | 190–600 nm |
Short term noise (ASTM) | ± 0.75 × 10-5 AU at 254 nm |
Drift | 3 × 10-4 AU/hr at 254 nm |
Linearity | > 2 AU (5%) upper limit |
Wavelength accuracy | ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter |
Band width | 6.5 nm typical |
Flow cells | Standard: 14-µl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum High pressure: 14-µl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum Micro: 1-µl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum Semimicro: 5-µl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum |
Analog outputs | Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, one output |
Dimensions | 14x19x24" |
Weight | 25 lbs |
Power | 100-240 V, 50/60Hz, 85W, 290 BTU |
- Agilent G1314A VWD Detector
- Validation Report with Clean Bill of Health
- 115V Power Cord
- 30-Day Warranty
- Please note: Laptop is not included any only shown in pictures as proof the detector was properly validated
This Agilent G1314A VWD Detector has been fully inspected and is performing without issue. All of our lab equipment comes backed with our standard warranty. Should you have any questions, please don't hesitate to contact us.