The BioTek plate reader Synergy HT offers you single-channel absorbance, luminescence and fluorescence reading in a compact easy to use system. This BioTek instrument is computer-controlled with powerful Gen5 data analysis software to help control and analyzer collected data quickly and efficiently. The Synergy HT works with all standard plates ranging in size from 6 to 384-wells as well as PCR tubes up to 1.25” in height when used with adapter plates.
This multi-mode microplate reader has a dual optic design, that includes separate fluorescence and absorbance channels, with 3 mm top and 5 mm bottom fluorescence probes. The high-performance Synergy HT multi detection microplate uses filters, a photon multiplier tube, and a long-lasting tungsten halogen lamp. These features help provide the most constant light and high levels of repeatable sensitivity.
The BioTek Synergy HT microplate reader can be customized with different filters and bandpasses. The plate reader filters are specifically designed to prevent light leakage from excitation to emission wavelengths. The absorbance wavelength range is between 200 - 999 nm adjustable in 1 nm increments. The low noise PMT with a digital photon mode provides optimal detection in luminescence mode, 300-650nm in excitation and 300-700 nm in emission.
When in absorbance mode, the synergy ht multi detection microplate reader switches to different Xenon Flash Lamp which allows the detection of UV and visible light. This plate reader also has a temperature control system for uniform kinetic assays. For the best in optimization, and automation, this system is BioStack ready and is compatible with a wide range of automated systems.
BioTek Synergy HT Plate Reader Specifications:
Detection Mode | Absorbance (UV/Vis), Luminescence, Fluorescence |
Read Method | Kinetic, End Point, Spectral Scanning, Well Area Scanning |
Temperature Control | 4°C above ambient to 50°C ± 0.5°C at 37↑8C |
Shaking | Low, Medium, High and Variable, Duration programmable |
Plate Formats | 6 to 384 well plates, |
Absorbance Specifications: |
|
Wavelength Selection | Monochromator |
Wavelength Range | 200 - 999nm, 1nm increments |
Bandpass | 2.4 nm |
Dynamic Range | 0 - 4.0 OD |
Resolution | 0.001 OD |
Monochromator Wavelength Accuracy | ±0.2nm |
Monochromator Wavelength Repeatability | ±0.2nm |
Fluorescence Specifications: |
|
Sensitivity | Fluorescein 5 pM typical |
Wavelength Selection | Deep blocking fliters |
Excitation Range | 300 - 650 nm |
Emission Range | 300-700 nm |
Dynamic Range | 5 decades |
Detection System | PMT |
Reading Speed | 96 well at 31 seconds, 384 wells at 80 seconds |
Luminescence Specifications: |
|
Sensitivity | 30 amol ATP typical (flash) |
Wavelength Range | 300 - 700 nm |
Dynamic Range | > decades |
Detection system | Low noise PMT |
General: |
|
Power | 100 - 240 VAC 50/60Hz |
Dimensions | 16" x 15" x 10" (L x W x H) |
Weight | 40 lbs |
- Biotek Synergy HT | CAT# SIAFR
- Windows 10 Computer Running Gen 5 Software
- Absorbance Validation Report
- Fluorescence Validation Report
- Excitation Filters 360/40, 485/20, 530/25, 590/20
- Emission Filters 460/40, 528/20, 590/35, 645/40
- Communication Cable
- Biotek Synergy User Manual
- 120V Power Cord
- 30-Day Warranty
This Biotek Synergy HT Multi Detection Plate Reader SIAFR has been fully inspected and come with current validation reports. All of our lab equipment comes backed by our standard warranty. Should you have any questions, please don't hesitate to contact us.