Lonza PyroWave XM Fluorescence Microplate Reader

  • The Lonza PyroWave XM Fluorescence Microplate Reader is available from The Lab World Group sellers of quality used microplate readers
  • The Lonza PyroWave XM Fluorescence Microplate Reader offers you reliable fluorescence reading of microplates
  • The Lonza PyroWave XM Fluorescence Microplate Reader has modular design for a high performance, expandable solution for your lab
  • The Lonza PyroWave XM Fluorescence Microplate Reader microplate reader is similar in construction to the Biotek H1F Microplate reader
  • The Lonza PyroWave XM Fluorescence Microplate Reader but has been optimized specifically for Lonza’s Pryogene assays
  • The Lonza PyroWave XM Fluorescence Microplate Reader features top read fluorescence with Endpoint Kinematic, and Well Area Scanning
  • The Lonza PyroWave XM Fluorescence Microplate Reader modular approach also means you can expand the fluorescent capabilities to time resolved fluorescence, luminescence and luminescence
  • The Lonza PyroWave XM Fluorescence Microplate Reader is outfitted with a Pyrogene filter cube, set with Excitation Filters 380/20 and 485/20 and Emission Filters 440/30 and 528/20
  • The Lonza PyroWave XM Fluorescence Microplate Reader uses Fluorescence - Top Read
  • The Lonza PyroWave XM Fluorescence Microplate Reader has Excitation Filters 380/20 and 485/20
  • The Lonza PyroWave XM Fluorescence Microplate Reader runs off a Xenon Flash Lamp and has a wavelength accuracy of ± 2nm
  • The Lonza PyroWave XM Fluorescence Microplate Reader has Emission Filters 440/30 and 528/20
  • The Lonza PyroWave XM Fluorescence Microplate Reader has been fully inspected and is operating without issue
  • The Lonza PyroWave XM Fluorescence Microplate Reader has Linear, Orbital, Double Orbital Shaking
  • The Lonza PyroWave XM Fluorescence Microplate Reader features 4 zone incubation to 45°C with condensation control ±0.2°C at 37°C
  • The Lonza PyroWave XM Fluorescence Microplate Reader reads 384 wells in 22 seconds
  • The Lonza PyroWave XM Fluorescence Microplate Reader reads at 96 wells in 11 seconds
  • The Lonza PyroWave XM Fluorescence Microplate Reader sensitivity is Fluorescein @ 1pM/well in a 96 well plate
  • The Lonza PyroWave XM Fluorescence Microplate Reader uses a PMT detector
  • The Lonza PyroWave XM Fluorescence Microplate Reader can be upgraded to 850 nm with an optional cube
  • The Lonza PyroWave XM Fluorescence Microplate Reader has a wavelength range of 200 – 700 nm
  • The Lonza PyroWave XM Fluorescence Microplate Reader uses a Xenon Flash Lamp
  • The Lonza PyroWave XM Fluorescence Microplate Reader works with 6-384 Well Plates labware height max: .89” / 22.6mm
  • The Lonza PyroWave XM Fluorescence Microplate Readerhas Endpoint Kinematic, Well Area Scanning read methods
  • The Lonza PyroWave XM Fluorescence Microplate Reader is Capable of Luminescence, TRF, FP with optional filter cubes

Category:

Microplate Readers

Manufacturer:

Other
SKU:
LONZOPYROWAVEXMMICROPLATEREADER-7501
Ships Within:
3 Business Days
Qty Available:
1

Price:

$7,699

REQUEST QUOTE

or Call 617-999-5746 for more information

"Want to sell your item like this one?"

  • EQUIPMENT DESCRIPTION
  • SPECIFICATIONS
  • INCLUDED
  • NOTES

The Lonza PyroWave XM Fluorescence Microplate Reader offers you reliable fluorescence reading of microplates with modular design for a high performance, expandable solution for your lab. This microplate reader is similar in construction to the Biotek H1F Microplate reader but has been optimized specifically for Lonza’s Pryogene assays. This microplate reader features top read fluorescence with Endpoint Kinematic, and Well Area Scanning at 200-700 nm, with the ability to move up to 850 nm, simply by swapping the filters within the system. This modular approach also means you can expand the fluorescent capabilities to time resolved fluorescence, luminescence and luminescence by adding modules available from Biotek. This fluorescence microplate reader is outfitted with a Pyrogene filter cube, set with Excitation Filters 380/20 and 485/20 and Emission Filters 440/30 and 528/20.  This microplate reader is also dispenser compatible, and features4 zone incubation to 45°C with condensation control, and linear shaking. The Pyrowave also features Gen5 software, a user-friendly operating system built to help guide users through set up and offers a selection of built in protocols. This plate reader runs off a Xenon Flash Lamp and has a wavelength accuracy of ± 2nm.

Lonza PyroWave XM H1M System Specifications:

Detection Modes

Fluorescence - Top Read

 

Capable of Luminescence, TRF, FP with option filter cubes

Read Methods

Endpoint Kinematic, Well Area Scanning

Microplate types

6-384 Well Plates (labware height max: .89” / 22.6mm)

Fluorescence Intensity

 

Lamp

Xenon Flash

Wavelength range

200 – 700 nm (850 nm option with separate cube)

Detection system

High Performance PMT detector

Sensitivity

Fluorescein @ 1pM/well in a 96 well plate

Reading Speed

96 wells: 11 seconds

384 wells: 22 seconds

Temperature control

4 zone incubation to 45°C with condensation control ±0.2°C at 37°C

Shaking

Linear, Orbital, Double Orbital

Dimensions (W x D x H)       

18x16x15”

Power

100 - 240V AC 50/60HZ

Weight

50 lbs.

 

  • Lonza PyroWave XM Fluorescence Microplate Reader | Similar to Biotek H1F
  • Windows 7 Notebook Gen5 Software
  • Fluorescence Validation Report with Clean Bill of Health
  • Excitation Filters 380/20 and 485/20
  • Emission Filters 440/30 and 528/20
  • Mirrors 400 and 510
  • 120V Power Cord
  • 30-Day Warranty

This Lonza PyroWave XM Fluorescence Microplate Reader has been fully inspected comes with current validations. All of out lab equipment comes backed with our standard warranty. Should you have any questions, please don't hesitate to contact us.

Other Microplate Readers