Agilent 8453 UV-Vis
Spectrophotometers
Agilent
Spectrophotometers Price
- EQUIPMENT DESCRIPTION
- SPECIFICATIONS
- INCLUDED
- NOTES
The Agilent 8453 UV-Vis spectrophotometer G1103A offers you fast results and repeatability in a compact footprint. This photodiode spectrophotometer eliminates scanning and measures across the ultra-violet to visible light spectrum to return spectral acquisition and analysis in less than one second. This UV-Vis spectrophotometer has stable optics and low noise with no moving parts, eliminating variables to get you reproducible results. This system has a wavelength scan of 190-1100 nm, and a 1nm slit width, cutting down on stray light to < 0.03 %.
The Agilent 8453 UV-Visible spectrophotometer supports compliance with GLP regulations, with its own clock for time and date stamps and self-test procedures to make sure performance is consistent in between validations. This spectrophotometer has an open sample area for easy loading of samples and makes large accessories easy to use. This system is ideal for labs needing to conform to GLP regulations, or for more generalized tasks. Users of this 8453 are guided through a graphical interface, that provides at a glance confirmation of actions and statuses, and quick access to frequently used programs. This Agilent 8453 is partnered with multicell transport, to help boost productivity in repetitive situations or when you want to follow changes in several samples. This 8-cell position transport can randomly access all positions moving between them in under 1 second, and a ± 0.1 mm position repeatability.
Agilent 8453 Spectrophotometer Specifications:
Wavelength range | 190–1100 nm |
Slit width | 1 nm |
EP resolution test | > 1.6 toluene in hexane, ratio abs. at 269 nm/266 nm |
Stray light | < 0.03 % at 340 nm (NaNO2, ASTM)< 0.05 % at 220 nm (NaI, ASTM)< 1 % at 198 nm (KCl, EP) |
Wavelength accuracy | < ± 0.5 nm 0.5-second scan (NIST 2034)< ± 0.2 nm at 486.0 and 656.1 nm |
Wavelength reproducibility | < ± 0.02 nm ten consecutive scans (NIST 2034) |
Photometric accuracy | < ± 0.005 A at 440.0, 465.0, 546.1, 590.0, and 635.0 nm, 1 A (NIST 930e)< ± 0.01 A at 235, 257, 313, 350, 430 nm,(potassium dichromate, EP method) |
Photometric noise | < 0.0002 A sixty 0.5 second scans at 0 A, 500 nm, rms |
Photometric noise | < 0.0002 A sixty 0.5 second scans at 0 A, 500 nm, rms |
Photometric stability | < 0.001 A/h at 0 A, 340 nm, after 1-hour warm up, measured over 1 hour, every 5 seconds, constant ambient temp. |
Baseline flatness | < 0.001 A 0.5-second blank, 0.5-second scan, rms |
Typical scan time | 1.5 second full range |
Shortest scan time | 0.1 second full range |
Time until next scan | 0.1 second full range, 0.1-second scan, up to 150 consecutive scans |
Dimensions | 24x16x8” |
Weight | 50lbs |
Power | 100-120/220-240V, 50/60 Hz |
- Agilent 8453
- Windows 7 Laptop Running Chemstation UV-Vis B.04.01 & Lab Advisor
- Single Cell Cuvette Sample Holder
- Communication Cable
- 120V Power Cord
- User Manual
- 30-Day Warranty
The Agilent 8453 comes fully calibrated and validated with a clean bill of health. Our service did a full quality control inspection on all boards, lamp and non-electronical parts. If any items were suspect, our service team will replaced with OEM parts to ensure the instrument meets factory specification. We then wiped the instrument down with 99% isopropyl alcohol as part of our decontamination process. Once this was done we ran our standard inbound QC testing on the instrument. Once Quality Control Testing was complete we ran a validation on the instrument with our reference standard to make sure system met manufacturer specifications. Our trained technicians ran a full wavelength scan along proper function test to guarantee system is beyond reproach. System passed all function tests and is ready to ship.
Specification Document: