Description
Agilent Biotek Synergy H1 F Microplate Reader
The BioTek Synergy H1 F plate reader is a high throughput, multiple detection microplate reader built on a performance, with a flexible modular platform and filter optics. The Synergy H1F can be read in full-light luminescence, filtered luminescence, and top reading filter/dichroic fluorescence, fluorescence polarization, and time-resolved fluorescence.
This Multi-Mode Plate Reader is ideally suited for various research assays such as cell-based, biomarker, micro-volume nucleic acid and protein analysis, and kinetic assays. Fluorescence Intensity has a sensitivity of 0.25 pM (0.025 fmol/well with a 384-well plate, and a dynamic range of 7 decades. Fluorescence Polarization has a wavelength range capability of 280-700nm.
The BioTek Gen5 software is extremely easy to use and has several built-in protocols to choose from. Some featured reads of the Synergy H1 plate reader includes endpoint analysis, well area scanning, spectral scanning, and kinetics, and a four-zone temperature controller up to 45°C with a built-in shaker. The Synergy H1F plate reader runs off a Xenon Flash Lamp with a wavelength accuracy of ± 2nm.
Specifications
Specifications
Agilent Biotek H1F Specifications
Detection Modes | Fluorescence Intensity, Luminescence, Fluorescence Polarization, Time-Resolved Fluorescence |
Read Methods | End point, kinetic, spectral scanning, well area scanning |
Temperature Control | 4-Zone incubation to 45°C |
Shaking | Linear, orbital, double orbital |
Software | Agilent BioTek Gen5 Software |
Automation Compatibility | Agilent BioTek BioStack microplate stacker |
Fluorescence Intensity | |
Light Source | Xenon Flash |
Detector | PMT for filter system |
Wavelength Selection | Filters (Top) |
Dynamic Range | 7 Decades |
Sensitivity | Fluorescein 0.25 pM (0.025 fmol/well, 384-well plate) |
Fluorescence Polarization | |
Light Source | Xenon flash |
Detector | PMT |
Wavelength Selection | Filters |
Wavelength Range | 280–700 nm (850 nm option) |
Sensitivity | 2 mP standard deviation at 1 nM fluorescein |
Time-Resolved Fluorescence | |
Light Source | Xenon flash |
Detector | PMT |
Wavelength Selection | Filters |
Sensitivity | < 40 fM |
Luminescence | |
Sensitivity | Filters: 10 amol ATP |
Reagent Dispensers | |
Number | 2 syringe pumps |
Supported Labware | 6- to 384-well microplates |
Dead Volume | 1.1 mL, with backflush |
Dispense Volume | 5–1,000 μL in 1 μL increments |
Dispense Accuracy | ± 1 μL or 2% |
Dispense Precision | < 2% at 50–200 μL |
Dimensions | 15x19x13” |
Weight | 50 lbs |
Electrical | 120V, 130W max |
Included
Included
Included with this Agilent Microplate Reader
Biotek Synergy H1 Multi-Detection Microplate Reader | CAT# H1F | Filter Based Flourescence & Luminescence | MSRP: $32,437.00
Windows 10 Laptop Runnin Gen5 Software
Blue Filter Installed
Green Filter Installed
System Validation Report
Fluorescence Validation Report
Communication Cable
User Manual
120V Power Cord (9A)
30-Day Warranty
Please Note: This is a Fluorescence and Luminescence system only.
Notes
Notes
Technical Notes
This microplate reader has been thoroughly tested and comes with a current validation report. All of our lab equipment comes backed by our standard warranty. Should you have any questions, please don’t hesitate to contact us.
Please Note: This is a Fluorescence and Luminescence system only.
Video
Video
Biotek Synergy H1F Video
Biotek Synergy H1F Microplate Reader Video ID 21317