Baker Biosafety Cabinet Class II A2 – Unused 2021

Availability: Out of stock SKU: 16250 Category:

Description

Baker Biosafety Cabinet Class II A2 – Unused 2021

The Baker SterilGARD Biosafety Cabinet is a Class II A2 cabinet that offers your lab vertical laminar airflow and HEPA filtration to keep users and samples safe from airborne contaminants. The Baker 404XD is especially ideal for use with a CytoFLEX cell sorter to provide a separate airfoil to reduce airflow turbulence and protection for personnel, product, and environment.

The SterilGARD Biosafety hood uses a momentum of 100 FPM through the access opening to protect users, creating a powerful and effective air barrier. Additionally, to protect the product the Sterilgard iii advance uses HEPA filtration is used for the downflow into the cabinet, and for exhausting out to the room.  When it comes time to change the HEPA filters for the scan tested supply and exhaust or this biosafety hood are installed in the front and are accessible without entering the work area.

This Sterilgard Biosafety Cabinet interior is corrosion resistant stainless steel, with one GFCI duplex outlet and solid one-piece construction. The working access height is 10” and the screen is set at a 10° angle for viewing comfort. Cabinet controls are set above the work area and it easy to reach and read from a sitting or standing position.

Specifications

Baker Sterilgard BSC Specifications:

Nominal Width 4 ft
Interior Dimension (w x d x h) 44X24X26
Air intake flow 105 FPM
Downflow velocity 45-55 FPM
Exterior Dimensions (w x d x h) 54X35X76
Operational Temperature Range 5° C to 40° C
Relative Humidity 80%
Cabinet Weight (lbs) 616lbs with Stand
Power 120 VAC 16A 60Hz

 

Included

Included with Sterilgard

2021 Baker Biosafety Cabinet | CAT# BEC404XD | Class II A2 | Unused Scratch Model | MSRP: $39,900.00
NEW HEPA Filters Installed
Lamp Installed
GFI Outlet Installed
Stand with Hardware
120V Power Cord (16A)
30-Day Warranty
Please Note: This listing is for a Baker BSC that’s been fully tested by our service team with a clean bill of health.  HEPA filters have been checked out to be in good, unused condition. We ran a flow meter on the hood to ensure the blower motor is up to spec and unit passed QC.  If your hood validation service provider requires new filters in order to pass their certification, it’s the buyer’s responsibility to purchase them. We are not responsible for your hood certification, this is buyer’s responsibility.  System is ideal for housing a Cytometer or Cell Sorter.

Notes

Notes on Sterilgard III Advance

Please Note: This listing is for a Baker BSC that’s been fully tested by our service team with a clean bill of health.  HEPA filters have been checked out to be in good, unused condition. We ran a flow meter on the hood to ensure the blower motor is up to spec and unit passed QC.  If your hood validation service provider requires new filters in order to pass their certification, it’s the buyer’s responsibility to purchase them. We are not responsible for your hood certification, this is buyer’s responsibility.