00 items
- You cannot add "Tecan Infinite F200 Fluorescence Microplate Reader" to the cart because the product is out of stock.
Sale
Biotek Synergy HT Microplate Reader Multi-Mode
$6,495
- Description
- Specifications
- Included
- Notes
- Video
Description
Description
Biotek Synergy HT Microplate Reader
The Biotek Synergy HT Microplate Reader is a multi-detection Microplate Reader with single-channel absorbance, luminescence, and fluorescence reading in a compact, easy-to-use system. This microplate reader is computer-controlled with powerful Gen 5 software to help control and analyze collected data quickly and efficiently. When used with adapter plates, the Synergy HT works with all standard plates ranging in size from 6 to 384 wells and PCR tubes up to 1.25″ in height.
This multimode microplate reader has a dual optic design that includes separate fluorescence and absorbance channels, with 3 mm top and 5 mm bottom fluorescence probes. The Synergy HT uses filters, a photon multiplier tube, and a long-lasting tungsten halogen lamp to provide the most constant light and high levels of repeatable sensitivity.
The Biotek Synergy HT Microplate Reader can be customized using different filters and bandpasses, with filters specifically designed to prevent light leakage from excitation to emission wavelengths. The absorbance wavelength range is between 200-999 nm, adjustable in 1 nm increments. This plate reader features a low-noise PMT with a digital photon mode for optimal detection in luminescence mode 300-650nm in excitation and 300-700 nm in emission.
In absorbance mode, the Synergy HT Microplate Reader switches to a different Xenon Flash Lamp, which detects UV and visible light. This plate reader also has a temperature control system for uniform kinetic assays. For the best optimization and automation, this system is BioStack-ready and compatible with a wide range of automated systems.
Please note: Time-resolved fluorescence module is not included
Specifications
Specifications
Synergy Ht Microplate Reader Specifications
Detection Mode | Absorbance (UV/Vis), Luminescence, Fluorescence |
Read Method | Kinetic, End Point, Spectral Scanning, Well Area Scanning |
Read modes | Normal, Rapid and Sweep |
Temperature Control | 4°C above ambient to 50°C ± 0.5°C at 37↑8C |
Shaking | Yes, Built-in, Low Medium, High and Variable |
Plate Formats | 6 to 384 well plates, |
Absorbance Specifications: | |
Wavelength Selection | Monochromator |
Detector | Photodiode (2) |
Wavelength Range | 200 – 999nm, 1nm increments |
Bandpass | 2.4 nm |
Dynamic Range | 0 – 4.0 OD |
Resolution | 0.001 OD |
Monochromator Wavelength Accuracy | ±0.2nm |
Monochromator Wavelength Repeatability | ±0.2nm |
Fluorescence Specifications: | |
Sensitivity | Fluorescein 5 pM typical |
Wavelength Selection | Deep blocking fliters |
Excitation Range | 300 – 650 nm |
Emission Range | 300-700 nm |
Dynamic Range | 5 decades |
Detection System | PMT |
Reading Speed | 96 well at 31 seconds, 384 wells at 80 seconds |
Luminescence Specifications: | |
Sensitivity | 30 amol ATP typical (flash) |
Wavelength Range | 300 – 700 nm |
Dynamic Range | > decades |
Detection system | Low noise PMT |
General: | |
Power | 100 – 240 VAC 50/60Hz |
Dimensions | 16″ x 15″ x 10″ (L x W x H) |
Weight | 40 lbs |
Included
Included
Included with Biotek Synergy HT
Please see individual SKU ID’s for a complete list of included items.
Notes
Notes
Technical Notes
This plate reader has been fully inspected and includes current reports for Absorbance and Fluorescence. Please note: Time-resolved fluorescence module and dispenser module is not included. All of our lab equipment comes backed by our standard warranty. Should you have any questions please don’t hesitate to contact us.