00 items
- Please choose product options by visiting Nova Biomedical Bioprofile Flex2.
GE Sievers 280i Nitric Oxide Analyzer
- Description
- Specifications
- Included
- Notes
- Video
Description
Description
GE Sievers 280i Nitric Oxide Analyzer
The GE Sievers 280i Nitric Oxide Analyzer is a versatile detection system built to analyze Nitric Oxide. The highly sensitive, ozone-chemiluminescence technology, gives the NOA 280i the versatility to measure both exhaled breath nitric oxide measurements quickly, and additional liquid measurements such as nitrite, nitrate, and nitrosothiols. Liquid applications can come from virtually any biological sample such as plasma, sera, uring, cerebral-spinal fluid, tissue homogenates, and more.
This analyzer can measure sample volumes from just a few microliters to several millimeters. This NOA analyzer is compact to conserve bench space, taking up a 7 x 22 in footprint. Using this Nitric Oxide Analyzer is simple, with menu-based software that provides complete analyzer control, and allows users to create, store and upload methods for access later. The onboard control also monitors operating time and alerts users when to replace consumables or when maintenance is needed.
Data is collected by this software for analysis including programs such as liquid, restricted exhaled breath, breath by breath, and bag sampling. Users can process this data over a wide range of sampling techniques. Consumables used with the NOA 280i are inexpensive, and only require replacement after 900 hours of use which averages to about 6 months making it low cost to maintain.
Specifications
Specifications
GE Sievers 280i Nitric Oxide Analyzer Specifications:
Liquid Samples | |
Sensitivity | 1 picomole (1 nM for a 1 mL injection) |
Range | Nanomolar to millimolar |
Repeatability | +/- 5% |
Sample | Volume: 0.001–1 mL |
Gas Samples | |
Sensitivity | 0.5 ppb |
Range | 0.5 ppb-500 ppm |
Repeatability | +/- 5% |
Sample | Flow rates: 10-200 mL/min |
General | |
Response Time | Electronics: 67 milliseconds to 90% full scale. Lagtime: 1 second |
Outputs | 1 analog 0-1V, 0-10V
1 digital RS-232 (9600-38400 Baud), 1 printer parallel port |
Data Sampling Rate | Operator selectable — 32, 16, 8, 4, 2,or 1 samples per second; or 12, 4, 2, 1, 0.2, or 0.1 samples per minute |
Dimensions | 7x22x16” |
Weight | 36lbs |
Power | 120V / 60hz / 10A/ 900W |
Included
Included
Included with GE Sievers 280i Nitric Oxide Analyzer
- GE Sievers 280i Nitric Oxide Analyzer
- User Manual
- 120V Power Cord (10A)
- 30-Day Warranty
Notes
Notes
Technical Notes
This GE Sievers 280i Nitric Oxide Analyzer has been fully inspected and is operating without issue. All of our lab equipment comes backed by our standard warranty. Should you have any questions please don’t hesitate to contact us.