Description
Description
Harvard Apparatus PHD Ultra and PHD 2000 Syringe Pumps
The Harvard Apparatus PHD syringe Pumps are built to handle either infusion or infusion and withdrawal. They provide high accuracy for flexible use in mass spectroscopy, calibration, drug and nutritional infusions, microdialysis, dispensing chromatography, and LC/HPLC applications. These microprocessor-controlled syringe pumps feature an easy-to-navigate full-color touch screen that displays operation in real time with on-screen graphics. This unit also comes with preprogrammed methods.
The small step-angle stepping motor of the PHD Ultra drives a lead screw and pusher block, with a step rate range of 26 µsec to 27 sec per µstep, to eliminate flow pulsation. Depending on the syringe, the flow rate is between 1.56 pl/min- 216 ml/min, with a flow accuracy of 0.35% and reproducibility within 0.05%. The accompanying software for the Harvard PHD Ultra and touch color display allows users to create methods from selecting common syringe models, inputting custom specifications, calculating cross-sectional areas, and calibrating the flow rate and volume accumulation.
The Harvard PHD 2000 Syringe Pump provides reliable and steady infusion with microprocessor control and high accuracy. This infusion pump holds two syringes and can hold syringes from 0.5uL to 140 mL. The flow rate of this syringe pump provides smooth advancement and super low rates, with a micro-stepping motor that can get down to 0.0001 uL/hour and is very quiet while operating. This infusion pump is simple to work with a digital, bright, easy-to-read display and numerical touch keypad. The Harvard PHD 2000 Syringe Pump delivers an average nominal force of 50 lbs and has an accuracy of 0.35% and a reproducibility within 0.05%.
Specifications
Specifications
Harvard Apparatus PHD Ultra Specifications:
Pump Function | Infusion Only (70-3005)
or Infuse/Withdraw, Programmable (70-3007) |
Accuracy | ±0.25% |
Drive Motor | 0.9° Stepper Motor |
Flow Rate Maximum | 216 ml/min using 140 ml syringe |
Flow Rate Minimum | 1.56 pl/min using 0.5 µl syringe |
Pusher Travel Rate Maximum | 190.8 mm/min |
Pusher Travel Rate Minimum | 0.18 µm/min |
Step Rate Maximum | 26 µsec/µstep |
Step Rate Minimum | 27.5 sec/µstep |
Max Linear Force | 75 lbs @ 100% Force Selection |
Mode of Operation | Continuous |
No of Syringes | 2 |
Syringe Size Maximum | 140 ml |
Syringe Size Minimum | 0.5 µl |
Number of Microsteps per one rev of Lead Screw | 12,800 |
Environmental Humidity | 20% to 80% RH, non condensing |
Environmental Operating Temperature English | 40°F to 104°F/4°C to 40°C |
Dimensions Control Box LxDxH in cm | 12.0 x 8.5 x 7.25 (30.48 x 21.59 x 18.42) |
Weight | 11 lbs |
Power | 100-240 VAC, 50/60 Hz 50 W, 0.5 A fuse |
Harvard PHD 2000 Syringe Pump Specifications:
Capacity From | 0.5 µl to 140 ml |
Flow Rate Range: | |
Minimum / Maximum | 0.0001 ul/hr – 220.82 mm/min |
Flow Rate Accuracy | ±0.35% |
Maximum Force | 50 lbs (23 kg) |
Drive Motor | 1/2 to 1/32 micro-stepping, microprocessor controlled, 1.8 |
Step Rate: | |
Minimum / Maximum | 27.3 sec/step – 416.7 usec/step |
Pusher Advance/Step | 0.082 µm pusher advance per motor step |
Pusher Travel Rate: | |
Minimum / Maximum | 0.18 um/min -190.676 mm/min |
Dimensions | 9 x 11 x 7” |
Weight | 11lbs |
Power Supply | 115/230V, 50/60Hz, 1/2amp |
Included
Included
Included with the Syringe Pump
Harvard Apparatus PHD Ultra Syringe Pump | CAT# 703005 | MSRP: $5,721.00
Multi-Head
Touch Screen Controller
User Manual
120V Power Cord (1A)
30-Day Warranty
Notes
Notes
Technical Notes
This syringe pump has been fully inspected and is operating without issue. All of our lab equipment comes backed by our standard warranty. Should you have any questions, please don’t hesitate to contact us.
Video
Video
Harvard Apparatus PHD Ultra Syringe Pump Video
Harvard Apparatus PHD Ultra Syringe Pump ID 19042