Tecan Infinite M1000 Microplate Reader

Availability: Out of stock SKU: 14730 Category:

Description

Tecan Infinite M1000 Microplate Reader

The Tecan Infinite M1000 is a Multilabel Microplate Reader that’s versatile, modular, monochromator-based, and adaptable to the changing needs of live science research and drug discovery.  Using Quad4 monochromators technology, this microplate reader gives your lab instant access and total freedom of wavelength selection from  230 to1000 nm, with absorbance, fluorescence intensity top and bottom detection. This microplate reader offers a staggering number of microplate formats, from 6 to 1536 well plates and the NanoQuant plate.

The Tecan Infinite M1000 Multi-Detection Microplate Reader features z-Optimization for low sample volumes, with an automated adjustment of z-focus. This dramatically improves the measurement quality in fluorescence intensity top and bottom modes by optimizing instrument set up and compensating for different parameters like low sample volume or varying well shapes. The fluorescence plate reader is extremely easy to use and takes minutes to set up.

The Tecan Infinite M1000 Multilabel Microplate Reader has an optimal read function for cell-based applications in 12 – to 96- well formats, performing multiple measurements on spatially separated spots. This feature, available in FI (fluorescence intensity) bottom reading mode, achieves maximum illumination and sensitivity across each well, for enhanced performance.

The Tecan Infinite M1000 Absorbance and Fluorescence Microplate Reader can execute double orbital shaking in addition to basic linear and orbital shaking. The plate transporter moves in a figure 8 pattern and is considered a more efficient method of mixing reagents and biomolecules, as well as keeping cells in suspension. The Tecan Infinite M1000 Multidetection Microplate Reader is compatible with Tecan’s NanoQuant Plate, an innovative quartz-based tool capable of measuring 16 samples simultaneously.

The Tecan Infinite M1000 Microplate Reader also features multi-channel absorbance, 3D scans when partnered with Magellan software, offers rapid visualization of fluorescent properties, as well as independently set bandwidths of excitation and emission, as well as AlphaScreen and AlphaLISA technology with temperature correction. The Tecan Infinite Plate Reader is fully capable of being integrated with the Tecan Freedom EVO for complete automation of assay setup, preparation, and detection.  Please see the included section for a breakdown of which modules are installed on these systems.

For added automation, the stacker module provides a means of loading and unloading microplates in two columns, an input stack, and an output stack.

The luminescence module allows users to analyze the activity of an enzyme-labeled compound. Luciferase reporter mechanisms offer a dynamic measurement window, that can record emission spectra of stable luminescent signals at 1 nm resolution. For best results, the instrument should be powered up for at least 15 minutes prior to the most stable environment.

Please be sure to check the modules and includes to make sure the specific system that has the readings you require. If you have questions, please don’t hesitate to contact us.

Specifications

Specifications of Tecan Infinite M1000 Microplate Reader

Light sources High energy xenon flash lamp, light-emitting diodes, laser-diode
Wavelength selection Premium Quad4 Monochromators
Plate formats 6 – 1,536-well plates, NanoQuant Plate
Absorbance
Bandwidth Absorbanc Scan 2.5 nm  <300nm

5 nm  >300 nm

Measurement range 0-4 OD
Wavelength Accuracy ± 0.3 nm
Wavelength reproducibility ± 0.3 nm
Wavelength Range 230 – 1000 nm in 1nm steps
Detector UV Silicon photodiode, 4-channel parallel reading
Fluorescence
Bandwidth Adjustable ≤ 300 nm: 2.5 – 10 nm; > 300 nm: 5 – 20 nm
Wavelength Accuracy ≤ 300 nm: ± 0.5 nm; > 300 nm: ± 1 nm
Wavelength reproducibility ≤ 300 nm: ± 0.5 nm; > 300 nm: ± 1 nm
Wavelength Range Ex: 230 – 850 nm

Em: 280 – 850 nm

Detector Extended wavelength (UV and far red)

Low dark current PMT

Fluorescence Polarization (Module Dependent, See model)
Standard LED Ex 470 nm. 530 nm, 590 nm, 635 nm
Emission WavelengthRange Em: 280 – 850 nm
Emission Bandwidth Selectable between 5-20nm
Luminescence (Module Dependent, See model)
Wavelength range 400-700 nm
Dynamic Range 6 decades
Dual Color Luminescence (Module Dependant, See model)
Integration time 100-20000 ms, different integration times are possible for each wavelength.
Flash luminescence 12 amol/well ATP (Greiner 384-well white plate; 55 µl)
Temperature control Ambient +4 to 42 °C
Shaking Linear, orbital, double orbital with variable amplitudes
Dimensions (L x W x H) 20x20x10 w/o stack

21 x 28 x 31″ w/ stack

Weight (lbs) 65 lbs
Power 100-120, 220-240V, 50/60 Hz

 

 

Included

Included with Tecan Infinite M1000 Microplate Reader

Please see individual SKU ID’s for a complete list of included items.

Notes

Technical Notes on Tecan Infinite M1000 Microplate Reader

This Tecan System has been tested and in excellent working condition. All of our Tecan Plate Reader models come backed with our standard right of return warranty. Each Tecan Microplate Reader comes complete with a computer running control software and cables.  Should you have any questions, please don’t hesitate to contact us.

Video

Video of Tecan Infinite M1000 Microplate Reader

ID 14381

Tecan Infinite M1000 Microplate Reader ID 14381

ID 14556

Tecan Infinite M1000 Microplate Reader ID 14556

ID 14730