Tecan Safire 2 Multi-Detection Plate Reader with Abs + FL

Availability: Out of stock SKU: 11087 Category:

Description

Tecan Safire 2 Plate Reader

The Tecan Safire 2 is a multi-detection microplate reader with Tecan’s quad4 technology that takes four monochromators a step above the standard. Flexible, sensitive, accurate, and fast, the Safire II has the essential benefits optimized by stray light reduction. A quad-four monochromator also gives users a true spectral scan by eliminating cut-off filters and increasing the fluorescence speed. This easy-to-use multi-mode microplate reader reads in Fluorescence Intensity top, bottom, and multi-channel absorbance, incorporating temperature control and shaking.

The Safire 2 features 16 slit options on each of the excitation and emission side. This Tecan plate reader has a wavelength spectrum array from 230-1000nm for absorbance testing and 230-850 nm for fluorescence excitation emissions and is operable at temperatures from 4-42°C.  Tecan is a well-known and reputable maker of fluorescence plate readers with additional options, including stacker modules from Tecan that boost efficiency to more than satisfy your monochromator reader desires.

Specifications

Tecan Safire 2 Plate Reader Specifications:

Plate formats 6 to 1536 well plates
Detectors Fluorescence- Extended wavelength, low dark current PMT

Absorbance- UV Silicon photodiode, 4 channel parallel reading

Temperature control Ambient + 4 °C to 42 °C
Shaking linear, orbital, 3 velocities
Fluorescence Intensity
Wavelength selection  Quad-4 Monochromator, 2 ex 2 em
Wavelength range Excitation: 230 – 850 nm,

emission: 280 – 850 nm

Bandwidth Adjustable from 2.5 nm – 10 nm below 280 nm, 5 nm – 20 nm else
Wavelength accuracy ± 1 nm
Wavelength precision ± 1 nm
Sensitivity – top reading
– 384 well plate 0.2 fmol / well Fluorescein
Sensitivity – bottom reading
– 384 well plate 0.6 fmol / well Fluorescein
Time Resolved Fluorescence
Sensitivity* – 384 well plate 60 amol / well Europium
Precision – 384 well plate 3 mP standard deviation @ 1nM Fluorescein
Absorbance
Wavelength Selection Double monochromator
Wavelength range 230 – 1000 nm
Bandwidth 2.5 nm below 280nm, 5 nm else
Wavelength accuracy ± 1 nm
Wavelength precision ± 1 nm
Measurement range 0 – 4OD
Accuracy @ 492 nm 0 – 2OD: ± 1% and 0.006OD
Precision @ 492 nm 0 – 2OD: ± 0.5% and 0.005OD
Interface connections RS 232 serial & parallel port
Software Driven YES
Power 115-120V / 220-240V 50/60Hz
Dimensions 21x23x11”
Weight 90 lb

Included

Included with Tecan Safire 2 Plate Reader

  • Tecan Safire II Multi-Detection Microplate Reader
  • Laptop Running Magellan Software
  • Absorbance Validation Report
  • Absorbance Option Installed
  • Fluorescence Validation Report
  • Fluorescence Top Option Installed
  • Fluorescence Bottom Option Installed
  • 120V Power Cord (4A)
  • User Manual
  • 30-Day Warranty