00 items
- You cannot add "Millipore Chromatography Column" to the cart because the product is out of stock.
Waters 2487 Dual Wavelength Absorbance Detector
- Description
- Specifications
- Included
- Notes
- Video
Description
Description
Waters 2487 Dual Wavelength Absorbance Detector
The Waters 2487 Dual Wavelength Absorbance Detector is a tool used for in-vitro diagnostic testing for a variety of compounds in HPLC applications. This absorbance detector uses two channels and has a tunable UV-Vis detector. This versatile Waters Detector can be used by itself with standalone programmability, as a component in a Waters Chromatography System, or even as a spectrophotometer with the proper Cuvette qualification kit. The Waters 2487 operates from 190 to 700 nm and can be used to monitor absorbance at a single or dual discrete wavelength.
The Waters 2487 has method editing and storage, and full diagnostics for optimal performance, accessible from the upfront control panel. This HPLC absorbance detector will store up to 10 user-defined programs with 16 timed steps and 2 threshold events each. The Waters 2487 Dual Wavelength Absorbance Detector also features wavelength verification reference, automatic second-order filtering for wavelengths 370nm and greater, and supports spectrum scan, display, subtraction, storage, and playback, in addition to standard tunable absorbance and UV/Vis functionality. For added convenience this detector is backward compatible, operating as a 486 Detector with PowerLine, Millennium32 software versions lower than 3.0, and other Waters products connected via the LAC/E interface using the IEEE-488 bus.
Specifications
Specifications
Waters 2487 Sku ID 10483 (Analytical Flow Cell) Specifications:
Wavelength range | 190 to 700 nm |
Bandwidth | 5 nm |
Wavelength accuracy | +1 nm |
Wavelength repeatability | +0.10 nm |
Noise, single wavelength | < +0.35 x 10-5 AU, dry cell, 254 nm, 1.0 sec. time constant (TC) |
Noise, dual wavelength | < +2.5 x 10-5 AU, dry cell, 254 nm / 280 nm,2.0 sec. time constant (TC) |
Drift | 1.0 x 10-4 AU/hour/° C at 254 nm (after 1 hour warmup) |
Sensitivity setting range | 0.0001 to 4.0000 AUFS |
Filter setting range Single wavelength | 0.1 to 5.0 seconds, Hamming (default), 1 to 99 seconds, RC |
Dual wavelength | 1 to 50 seconds, Hamming (default), 1 to 99 seconds, RC |
Optical Component Specifications | |
Lamp source | Deuterium arc lamp |
Flow cell | TaperSlit Flow Cell design |
Path length | 10 mm (standard analytical) |
Cell volume | 10 µL (standard analytical) |
Pressure limit | 1000 psi / 70 bar |
Sample Tube Internal Diameter | 0.009 in and out |
Operating Environmental Tolerances | 4 to 40 °C (39 to 104 °F), 20 to 80% rH, noncondensing |
Storage Environmental Tolerances | –40 to +70 °C (–40 to +158 °F), 20 to 80% rH, noncondensing |
Power | 100 to 240 Vac, 50 to 60 Hz |
Dimensions | 11x20x8” |
Weight | 20lbs |
Waters 2487 Sku ID 10484 (Semi Prep Flow Cell) Specifications:
Wavelength range | 190 to 700 nm |
Bandwidth | 5 nm |
Wavelength accuracy | +1 nm |
Wavelength repeatability | +0.10 nm |
Noise, single wavelength | < +0.35 x 10-5 AU, dry cell, 254 nm, 1.0 sec. time constant (TC) |
Noise, dual wavelength | < +2.5 x 10-5 AU, dry cell, 254 nm / 280 nm,2.0 sec. time constant (TC) |
Drift | 1.0 x 10-4 AU/hour/° C at 254 nm (after 1 hour warmup) |
Sensitivity setting range | 0.0001 to 4.0000 AUFS |
Filter setting range Single wavelength | 0.1 to 5.0 seconds, Hamming (default), 1 to 99 seconds, RC |
Dual wavelength | 1 to 50 seconds, Hamming (default), 1 to 99 seconds, RC |
Optical Component Specifications | |
Lamp source | Deuterium arc lamp |
Flow cell | TaperSlit Flow Cell design |
Path length | 3 mm Semi-Prep |
Cell volume | 2.6 µL |
Sample Tube Internal Dimameter | 0.040 in and out |
Pressure limit | 1000 psi / 70 bar |
Operating Environmental Tolerances | 4 to 40 °C (39 to 104 °F), 20 to 80% rH, noncondensing |
Storage Environmental Tolerances | –40 to +70 °C (–40 to +158 °F), 20 to 80% rH, noncondensing |
Power | 100 to 240 Vac, 50 to 60 Hz |
Dimensions | 11x20x8” |
Weight | 20lbs |
Included
Included
Included with Waters Dual Wavelength Detectors
Waters 2487 Dual Absorbance Detector
120V Power Cord
30-Day Warranty
Notes
Notes
Technical Notes
This Waters 2487 Dual Wavelength Absorbance Detector has been fully inspected and is ready to ship. All of our lab equipment comes backed by our standard warranty. Should you have any questions, please don’t hesitate to contact us.
Video
Video
Waters Dual Wavelength Detector Video
Waters 2487 Dual Absorbance Detector for Sale