00 items
LiCor Odyssey Imaging System 9120
- Description
- Specifications
- Included
- Notes
- Video
Description
Description
LiCor Odyssey Imaging System 9120
The LiCor Odyssey Infrared Imaging System 9120 gives your lab clear sharp digital results without the background fluorescence. By using digital images, strong and weak bands are detected on the same blot, saving lab time by not waiting on film to develop or the uncertainty of whether a weak band requires multiple exposures to confirm. The LiCor Odyssey employs direct infrared fluorescence detection for Western Blot applications to count low plentiful proteins.
The LiCor Odyssey 9120 uses two solid-state diode lasers for excitation at 685 and 785 nm, Collimating lenses, optical bandpass filters, and a focusing lens to tune the beams, and then microscope electronics modulate the lasers to discriminate IR fluorescence from background fluorescence. This imager is flexible enough for other applications as well, such as EMSA, In-Cell Western Assays, in vivo imaging, protein arrays, Coomassie gel documentation, tissue section analysis, and GNA gel documentation.
The Odyssey Imaging System 9120 features a wide linear range, two-color detection and quantification, high sensitivity, accurate detection of strong or weak signals, and nir fluorescence. The signals are stable and can be detected indefinitely if stored properly for accurate results. Contact us with any questions regarding our LiCor Odyssey Imager.
Specifications
Specifications
9120 Imaging System Specifications:
Laser Source | 700 channel: 685 nm, solid state diode
800 channel: 785 nm solid state diode |
Detector | Silicon avalanche photodiodes. |
Scanning Speed: | 5-40 cm/s |
Scanning Surface | 25 x 25 cm |
Resolution: | 21-337 µm |
Focusing: | Scan bed is movable in the Z-dimension, allowing the fluorescence detection microscope to be aligned to the top surface of the glass to obtain the best signal-to-noise ratio. |
Dimensions (L x W x H) | 15x22x24″ |
Weight | 72 lbs |
Power | 100-127/200-240 V, 50/60Hz, 8/5 amps |
Included
Included
Included with 9120 Imaging System
Li-Cor Odyssey 9120 Imager
Windows 10 Laptop with Image Studio 5.2
In Cell Western (ICW Installed)
System Validation Report with Calibration
Communication Cable
User Manual
120V Power Cord
30-Day Warranty
Notes
Notes
Technical Notes
This system has been fully calibrated and we’ve provided current validations. Reports can be viewed in the photo gallery and the imager comes with a clean bill of health. All of our lab equipment comes backed by our standard warranty. Should you have any questions, please don’t hesitate to contact us.
Video
Video
LiCor Odyssey 9120 Imaging System Video
Licor Odyssey 9120 Video ID 24465