Theย Agilent HPLC 1200ย provides a modular solution allowing users to customize to meet their Chromatography needs. This HPLC system is built to boost product development and provide robust analysis, with superior resolution, speed, and heightened sensitivity. The 1200 series HPLC system components can either be used individually through a controlling PC or a as plug and play stack that automatically handshakes with each other. Theย Agilent HPLC 1200 consists of a G1322A Degasser, G1311A Quat Pump, G1365 MWD Detector, G1316A Thermostated Column Compartment, G1329A ALS Autosampler, and a G1362A RID Refractive Index Detector.ย
ย
This HPLC multi-wavelength diode detector allows for flexible slit settings for a range of 1 to 16 nm and covers a range from 190-950 nm letting you customize the desired sensitivity, linearity, and spectral resolution. ย This Agilent HPLC stack is also configured with a G1322A Vacuum Degasser for best flow stability, especially at low flow rates, for maximum detector sensitivity. The degasser gives you a stable flow rate solution, that monitors pressure and adjusts the pump on and off as solvents pass through the membranes to remove gasses almost entirely.
ย
The G1316C TCC Thermostat Column Compartment is built to handle Peltier heating and cooling and holds up to three 30cm columns. Additionally, This Agilent 1200 series has a universal detector in the G1362A Refractive Index Detector, built for optical performance and GLP compliance, with incorporated calibration and auto light intensity circuit control. This HPLC System also comes with a controlling PC installed with Chemstation software to help manage and interpret large amounts of data collected from the system. The Chemstaion software is windows based, and user-friendly and gives you level 5 control of your instrument with built-in diagnostics and early warnings for maintenance.ย
| G1365D MWD Detector | |
| Detection type | 1024-element photodiode array |
| Light source | Deuterium and tungsten lamps |
| Data Rate | Up to 80 Hz |
| Wavelength range | 190 โ 950 nm |
| Short term noise | < ยฑ 0.7ยท10-5 AU at 254 and 750 nm |
| Drift | < 0.9 x 10 -3 AU/hr, at 254 nm |
| Linear absorbance range | > 2 AU (upper limit) |
| Wavelength accuracy | ยฑ 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter |
| Wavelength bunching | 1 โ 400 nm Programmable in steps of 1 nm |
| Slit width | 1, 2, 4 , 8, 16 nm Programmable slit |
| Diode width | ย < 1 nm |
| Flow cell Standard | 13-ยตL volume, 10 mm cell path length, 120 bar (1760 psi) pressure maximum |
| Vacuum Degasser | |
| Flow rate | 0-5 ml/min per channel
5-10 ml/min at reduced degassing performance |
| Number of channels | 4 |
| Internal volume per channel | Typically 1 ml per channel |
| Materials in contact with solvent | PTFE – PEEK |
| pH range | 1 โ 14 |
| Analog output (AUX) | For pressure monitoring, range 0 โ 3 V |
| G1362A RID Refractive Index Detector | |
| Detection type | Refractive index |
| Refractive index range | 1.00 – 1.75 RIU, calibrated |
| Measurement range | ยฑ600 x 10-6 RIU |
| Optical zeroing | via set screw |
| Optics temperature control | Ambient +5ยฐ to 55ยฐC |
| Sample Cell | volume 8uL; maximum pressure 5 bar (0.5Mpa); maximum flow rate 5mL/minute |
| Valves | Automatic purge and automatic solvent recycle |
| Volumes | Inlet port to sample cell 62ul, inlet port to outlet port 590ul |
| Liquid contact materials | 316 stainless steal, teflon and quartz glass |
| pH range | 2.3 – 9.5 |
| Performance specifications | Short term noise < ยฑ2.5 x 10-9 RIU, Drift < 200 x 10-9 RIU/hour |
| Time programmable parameters | polarity, peakwidth |
| Detector zero | automatic zero before analysis |
| G1311A Quat Pump | |
| Hydraulic system | Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve |
| Setable flow range | 0.001 โ 10 ml/min, in 0.001 ml/min increments |
| Flow range | 0.2 โ 10.0 ml/min |
| Flow accuracy | ยฑ 1% or 10 ยตl/min whatever is greater |
| Pressure Operating Range | 0 โ 40 MPa (0 โ 400 bar, 0 โ 5880 psi) up to 5 ml/min |
| Operating range | 0 โ 20 MPa (0 โ 200 bar, 0 โ 2950 psi) up to 10 ml/min |
| Recommended pH range | 1.0 โ 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel |
| G1329A ALS Auto Sampler | |
| Injection range | ย 0.1 โ 100 ยตl in 0.1 ยตl increments |
| Replicate injections | 1 โ 99 from one vial |
| Precision | < 0.25% RSD from 5 โ 100 ยตl, < 1% RSD 1 โ 5 ยตl variable volume |
| Minimum sample volume | 1 ยตl from 5 ยตl sample in 100 ยตl microvial, or 1 ยตl from 10 ยตl sample in 300 ยตl microvial |
| Carryover Typically | < 0.1%, < 0.05% with external needle cleaning |
| Sample viscosity range | 0.2 โ 50 cp |
| Replicate injections per vial | 1 โ 99 |
| Sample capacity | 100 ร 2-ml vials in 1 tray 40 ร 2-ml vials in ยฝ tray 15 ร 6-ml vials in ยฝ tray Agilent vials only) |
| Injection cycle time | Typically 50 s depending on draw speed and injection volume |
| G1316A TCC Thermostated Column Compartmentย | |
| Temperature Range | 10ยฐ below ambient to 80ยฐ C |
| Temperature Stability | ยฑ 0.15ยฐC |
| Temperature Accuracy | ยฑ 0.8ยฐC |
| Column Capacity | Three 30cm columns |
| Warm Up/Cool Down | 5 mins from ambient to 40ยฐC |
| Dead Volume | 3 ยตl left heat exchanger
6 ยตl right heat exchanger |
| General | |
| Dimensions | 16 x 18 x 37โ |
| Power | 100-120/220-240 V, 50/60 Hz |
This Agilent 1200 HPLC System and all of its components have been fully inspected and are operating without issue. All of our lab equipment comes backed with our standard warranty. Should you have any questions, please don’t hesitate to contact us.